Skip to content

How-to's and resources for upgrading NEJE desktop USB laser engravers

Notifications You must be signed in to change notification settings

xunker/neje_laser_upgrades

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

7 Commits
 
 
 
 
 
 

Repository files navigation

neje-laser-upgrades

How-to's and resources for upgrading the NEJE (also sold under the HICTOP brand, and others) desktop USB laser engraver to full GRBL compatibility by replacing the electronics.

Last updated January, 2018.

Full grbl upgrade with Arduino CNC Shield

Videos

I have uploaded a video of the whole upgrade process at youtu.be/2rbzI-d-bOA.

A second video with specific focus on the wiring, and that covers use of a MOSFET to switch the laser, is also available at https://youtu.be/MuKYvifYnYs.

Links to resources

Software-only upgrade

If you are lucky enough to have a machine that can be upgraded without replacing the board, you can follow these instructions to flash a new version of grbl to it.

Hardware

NEJE DK-8-KZ Engraver

The engraver pictured above and in the video: KKmoon NEJE DK-8-KZ 1000mW

The Arduino shield used to control the steppers: Arduino CNC Shield. I think I mistakenly referred to this as "grblshield" in the video.

Arduino Uno, the board that connects to the shield above.

Laser focus adjustment ring.

IRF520 module, the board that controls power to the 5V laser.

Software

Universal Gcode Sender - Used to send commands to the laser.

J Tech Photonics Laser Tool - Used to convert images to laser commands.

Wiring diagrams and schematics

Connecting PC power supply to Arduino and Shield

The CNC shield can accept any DC voltage from 12V to 36V. Because the stepper motors used here are very small, the 12V does not need to be high amperage; 500ma or larger will probably be sufficient.

CNC Shield Power schematic

CNC Shield Connections annotated

To power the upgrade, I used a power supply designed to run an internal PC hard drive, although a full-size PC power supply would work.

PC Power Supply Molex schematic

The most important part of the power supply is that is can give 5V at several amps to power the laser.

The CNC shield electronics can then be powered from 5V as well, but I chose to power them from the 12V rail of the power supply. If you choose to do that, you will want to adjust the current-limit on the drivers to avoid damaging the stepper motors. Details of how to do this are in the video.

Connecting stepper motors to the shield

The connector for the stepper motors are between the "drivers" (the red square circuit boards in this image.

With the white wire facing up, match the 4-pin connector on the cable to the 4-pin connector on the board for both the X- and Y-axis.

Stepper motor connections

Connecting laser to power supply and CNC shield

The SPNEN (SPiNdle ENable) pin on the shield cannot power the laser itself, so I use a circuit with a transistor to power the laser from the power supply, but still allow it to be turned on and off by the CNC shield.

First, you will connect the positive wire of the laser (coloured red on mine) to the 5V power line from your power supply. It MUST be 5V, any more will damage the laser!

We will switch the laser on and off by connecting or disconnecting the negative/ground wire. This technique is known as "low-side switching".

Here are two ways to do it, though there are probably other ways too. I recommend using a MOSFET over a TIP120. But if you only have a TIP120 it will still work though your laser power may suffer.

MOSFET circuit

An efficient way to switch the laser on and off is to use an N-Channel Power MOSFET. Currently I am using an IRF520 module like this one, but this is not designed for logic-level switching so if you have the option I would recommend using a logic-level MOSFET instead.

But, regardless of the voltage, if you want to solder one yourself then the circuit will look something like this:

MOSFET Laser Trigger schematic

This will switch the laser on and off with a minimum of voltage loss.

If you use the same IRF520 module that I did, here is how the wires are connected:

IRF520 module connections

TIP120 circuit

Before using the MOSFET, I was using a TIP120 Darlington transistor. This works but it is a poor choice because the voltage drop on a TIP120 can be as much as 2V in some cases. If we were switching 48V then that wouldn't be a problem but for a 5V laser, losing even 1V is going to severely impact laser power.

Here is the TIP120 switching circuit I used before:

TIP120 Laser Trigger schematic

TIP120 Laser Trigger breadboard

The transistor I used is a TIP120 "Darlington" transistor. It is a very common "power transistor" that you can find at any electronics shop (Radio Shack, Fry's, etc) and everywhere online. You can use any similar NPN-type power transistor (such as the TIP31, etc) as long as it can handle the current. A standard 2N3904 transistor can't handle it, and while a 2N2222 may be able to handle it for lower-powered lasers, I would still recommend using a TIP-series transistor because they are still very inexpensive.

Note: I should really upgrade the above circuit to use a MOSFET instead of a power transistor. It shouldn't be that hard adapt it using the example from this page. It may also let us use PWM to control the intensity of the laser.

Orientation

The origin (X/Y at 0) coordinates should be at the lower-left of the of the stage. "Lower" here means nearest to front. Make sure moving each axis negatively will move toward that point, and moving each axis positively will move away from that point.

configuring grbl to work in positive space

For J Tech Photonics Laser Tool (in Inkscape), make sure to set the machine coordinates system to operate in positive space. You will do that by uncommenting the following line in config.h before you upload the grbl code to the Arduino:

#define HOMING_FORCE_SET_ORIGIN

grbl 1.1 settings for Arduino CNC Shield upgrade

Grbl 1.1e [‘$’ for help]
$0=10
$1=25
$2=0
$3=0
$4=0
$5=0
$6=0
$10=1
$11=0.010
$12=0.002
$13=0
$20=0
$21=0
$22=0
$23=0
$24=25.000
$25=500.000
$26=250
$27=1.000
$30=1000
$31=0
$32=0
$100=108.000
$101=108.000
$102=250.000
$110=5000.000
$111=5000.000
$112=500.000
$120=500.000
$121=500.000
$122=10.000
$130=27.000
$131=37.000
$132=200.000

Reset default work area

You will probably need to reset the default "work area". Do that with these two commands:

G10 L2 P1 X0 Y0 Z0
G54 X0 Y0 Z0

About

How-to's and resources for upgrading NEJE desktop USB laser engravers

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages