Skip to content
Thomas E. Horner edited this page Mar 12, 2019 · 4 revisions

About this

BH1620FVC is an analog current output ambient light sensor.

Features:

  • Spectral sensitivity close to human eyes sensitivity.
  • Output current in proportion to brightness.
  • Supply voltage operates from 2.4V to 5.5V
  • Built-in shutdown function
  • 3 steps controllable output current gain.
  • 1.8V logic input interface
  • Low sensitivity variation (+/-15%)

Specification

What Comments
Identifier BH1620FVC
Interface ADC
Provides illuminance lux (*)
Properties gain 0 = H-Gain mode
1 = M-Gain mode
2 = L-Gain mode
r1 Iout R1 resistance value, in ohms.
Default value is set to 5600 ohms.
Please, refer to the datasheet page 4 for more information about R1.
calibration Calibration data +/- lux
Datasheet

Notes

  • The gain must be set according to the illuminance range to be measured (datasheet page 5) through pins 3 and 4.
  • Once the gain is set, the programmer must set the gain property. By default the sensor expects an H-Gain setting.
  • Adjust r1 value to your needs.
  • Once the r1 is set, the programmer must set the r1 property. By default the sensor expects a r1 value of 5600 ohms.
  • The programmer can use the calibration property to correct sensor readings that may be influenced by the location of the sensor, such as when the sensor is mounted behind a protective glass.

Comments

(*)

lux Surfaces illuminated by
0.0001 Moonless, overcast night sky (starlight)
0.002 Moonless clear night sky with airglow
0.05–0.36 Full moon on a clear night
3.4 Dark limit of civil twilight under a clear sky
20–50 Public areas with dark surroundings
50 Family living room lights
80 Office building hallway/toilet lighting
100 Very dark overcast day
320–500 Office lighting
400 Sunrise or sunset on a clear day
1000 Overcast day: typical TV studio lighting
10,000–25,000 Full daylight (not direct sun)
32,000–100,000 Direct sunlight

Code

-- Attach BH1620FVC sensor to an external ADC (ADS1115) / channel 0
s = sensor.attach("BH1620FVC", adc.ADS1115, 0)

-- If your gain / r1 values differ from de default values uncomment the
-- following lines and set your values
-- s:set("gain", 0)
-- s:set("r1", 5600)
-- s:set("calibration", 0)

while true do
  print(s:read("illuminance"))
  tmr.delayms(500)
end

Back to sensor list