Notifications
You must be signed in to change notification settings - Fork 13
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Add initial unit tests and automated CI (#48)
- Loading branch information
Showing
8 changed files
with
724 additions
and
62 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,29 @@ | ||
name: CI | ||
on: | ||
push: | ||
branches: | ||
- main | ||
pull_request: | ||
types: [opened, synchronize, reopened] | ||
jobs: | ||
test: | ||
name: ${{ matrix.version }} - ${{ matrix.os }} - ${{ matrix.arch }} - ${{ github.event_name }} | ||
runs-on: ${{ matrix.os }} | ||
strategy: | ||
fail-fast: false | ||
matrix: | ||
version: ['1'] | ||
os: [ubuntu-latest] | ||
arch: [x64] | ||
steps: | ||
- uses: actions/checkout@v3 | ||
- uses: julia-actions/setup-julia@v1 | ||
with: | ||
version: ${{ matrix.version }} | ||
arch: ${{ matrix.arch }} | ||
- name: install | ||
shell: julia --color=yes --project=. {0} | ||
run: | | ||
using Pkg | ||
Pkg.instantiate() | ||
- run: julia --color=yes --project=. test/runtests.jl |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,214 @@ | ||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% | ||
%%%% %%%%% | ||
%%%% IEEE PES Power Grid Library - Optimal Power Flow - v21.07 %%%%% | ||
%%%% (https://github.com/power-grid-lib/pglib-opf) %%%%% | ||
%%%% Benchmark Group - Typical Operations %%%%% | ||
%%%% 29 - July - 2021 %%%%% | ||
%%%% %%%%% | ||
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% | ||
% | ||
% Power flow data for IEEE 14 bus test case. | ||
% This data was converted from IEEE Common Data Format | ||
% (ieee14cdf.txt) on 20-Sep-2004 by cdf2matp, rev. 1.11 | ||
% | ||
% Converted from IEEE CDF file from: | ||
% http://www.ee.washington.edu/research/pstca/ | ||
% | ||
% Copyright (c) 1999 by Richard D. Christie, University of Washington | ||
% Electrical Engineering Licensed under the Creative Commons Attribution 4.0 | ||
% International license, http://creativecommons.org/licenses/by/4.0/ | ||
% | ||
% CDF Header: | ||
% 08/19/93 UW ARCHIVE 100.0 1962 W IEEE 14 Bus Test Case | ||
% | ||
function mpc = pglib_opf_case14_ieee | ||
mpc.version = '2'; | ||
mpc.baseMVA = 100.0; | ||
|
||
%% bus data | ||
% bus_i type Pd Qd Gs Bs area Vm Va baseKV zone Vmax Vmin | ||
mpc.bus = [ | ||
1 3 0.0 0.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
2 2 21.7 12.7 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
3 2 94.2 19.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
4 1 47.8 -3.9 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
5 1 7.6 1.6 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
6 2 11.2 7.5 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
7 1 0.0 0.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
8 2 0.0 0.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
9 1 29.5 16.6 0.0 19.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
10 1 9.0 5.8 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
11 1 3.5 1.8 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
12 1 6.1 1.6 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
13 1 13.5 5.8 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
14 1 14.9 5.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000; | ||
]; | ||
|
||
%% generator data | ||
% bus Pg Qg Qmax Qmin Vg mBase status Pmax Pmin | ||
mpc.gen = [ | ||
1 170.0 5.0 10.0 0.0 1.0 100.0 1 340 0.0; % NG | ||
2 29.5 0.0 30.0 -30.0 1.0 100.0 1 59 0.0; % NG | ||
3 0.0 20.0 40.0 0.0 1.0 100.0 1 0 0.0; % SYNC | ||
6 0.0 9.0 24.0 -6.0 1.0 100.0 1 0 0.0; % SYNC | ||
8 0.0 9.0 24.0 -6.0 1.0 100.0 1 0 0.0; % SYNC | ||
]; | ||
|
||
%% generator cost data | ||
% 2 startup shutdown n c(n-1) ... c0 | ||
mpc.gencost = [ | ||
2 0.0 0.0 3 0.000000 7.920951 0.000000; % NG | ||
2 0.0 0.0 3 0.000000 23.269494 0.000000; % NG | ||
2 0.0 0.0 3 0.000000 0.000000 0.000000; % SYNC | ||
2 0.0 0.0 3 0.000000 0.000000 0.000000; % SYNC | ||
2 0.0 0.0 3 0.000000 0.000000 0.000000; % SYNC | ||
]; | ||
|
||
%% branch data | ||
% fbus tbus r x b rateA rateB rateC ratio angle status angmin angmax | ||
mpc.branch = [ | ||
1 2 0.01938 0.05917 0.0528 472 472 472 0.0 0.0 1 -30.0 30.0; | ||
1 5 0.05403 0.22304 0.0492 128 128 128 0.0 0.0 1 -30.0 30.0; | ||
2 3 0.04699 0.19797 0.0438 145 145 145 0.0 0.0 1 -30.0 30.0; | ||
2 4 0.05811 0.17632 0.034 158 158 158 0.0 0.0 1 -30.0 30.0; | ||
2 5 0.05695 0.17388 0.0346 161 161 161 0.0 0.0 1 -30.0 30.0; | ||
3 4 0.06701 0.17103 0.0128 160 160 160 0.0 0.0 1 -30.0 30.0; | ||
4 5 0.01335 0.04211 0.0 664 664 664 0.0 0.0 1 -30.0 30.0; | ||
4 7 0.0 0.20912 0.0 141 141 141 0.978 0.0 1 -30.0 30.0; | ||
4 9 0.0 0.55618 0.0 53 53 53 0.969 0.0 1 -30.0 30.0; | ||
5 6 0.0 0.25202 0.0 117 117 117 0.932 0.0 1 -30.0 30.0; | ||
6 11 0.09498 0.1989 0.0 134 134 134 0.0 0.0 1 -30.0 30.0; | ||
6 12 0.12291 0.25581 0.0 104 104 104 0.0 0.0 1 -30.0 30.0; | ||
6 13 0.06615 0.13027 0.0 201 201 201 0.0 0.0 1 -30.0 30.0; | ||
7 8 0.0 0.17615 0.0 167 167 167 0.0 0.0 1 -30.0 30.0; | ||
7 9 0.0 0.11001 0.0 267 267 267 0.0 0.0 1 -30.0 30.0; | ||
9 10 0.03181 0.0845 0.0 325 325 325 0.0 0.0 1 -30.0 30.0; | ||
9 14 0.12711 0.27038 0.0 99 99 99 0.0 0.0 1 -30.0 30.0; | ||
10 11 0.08205 0.19207 0.0 141 141 141 0.0 0.0 1 -30.0 30.0; | ||
12 13 0.22092 0.19988 0.0 99 99 99 0.0 0.0 1 -30.0 30.0; | ||
13 14 0.17093 0.34802 0.0 76 76 76 0.0 0.0 1 -30.0 30.0; | ||
]; | ||
|
||
% INFO : === Translation Options === | ||
% INFO : Phase Angle Bound: 30.0 (deg.) | ||
% INFO : Line Capacity Model: stat | ||
% INFO : Gen Active Capacity Model: stat | ||
% INFO : Gen Reactive Capacity Model: am50ag | ||
% INFO : Gen Active Cost Model: stat | ||
% INFO : Setting Flat Start | ||
% INFO : Line Capacity PAB: 15.0 (deg.) | ||
% INFO : | ||
% INFO : === Generator Classification Notes === | ||
% INFO : SYNC 3 - 0.00 | ||
% INFO : NG 2 - 100.00 | ||
% INFO : | ||
% INFO : === Generator Active Capacity Stat Model Notes === | ||
% INFO : Gen at bus 1 - NG : Pg=232.4, Pmax=332.4 -> Pmax=340 samples: 20 | ||
% INFO : Gen at bus 2 - NG : Pg=40.0, Pmax=140.0 -> Pmax=59 samples: 6 | ||
% INFO : Gen at bus 3 - SYNC : Pg=0.0, Pmax=100.0 -> Pmax=0 samples: 0 | ||
% INFO : Gen at bus 6 - SYNC : Pg=0.0, Pmax=100.0 -> Pmax=0 samples: 0 | ||
% INFO : Gen at bus 8 - SYNC : Pg=0.0, Pmax=100.0 -> Pmax=0 samples: 0 | ||
% INFO : | ||
% INFO : === Generator Reactive Capacity Atmost Max 50 Percent Active Model Notes === | ||
% INFO : Gen at bus 2 - NG : Pmax 59.0, Qmin -40.0, Qmax 50.0 -> Qmin -30.0, Qmax 30.0 | ||
% INFO : | ||
% INFO : === Generator Active Cost Stat Model Notes === | ||
% INFO : Updated Generator Cost: NG - 0.0 20.0 0.0430293 -> 0 7.92095063323 0 | ||
% INFO : Updated Generator Cost: NG - 0.0 20.0 0.25 -> 0 23.2694943686 0 | ||
% INFO : Updated Generator Cost: SYNC - 0.0 40.0 0.01 -> 0 0.0 0 | ||
% INFO : Updated Generator Cost: SYNC - 0.0 40.0 0.01 -> 0 0.0 0 | ||
% INFO : Updated Generator Cost: SYNC - 0.0 40.0 0.01 -> 0 0.0 0 | ||
% INFO : | ||
% INFO : === Generator Bounds Update Notes === | ||
% INFO : | ||
% INFO : === Base KV Replacement Notes === | ||
% WARNING : Bus 1 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 2 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 3 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 4 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 5 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 6 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 7 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 8 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 9 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 10 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 11 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 12 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 13 : basekv changed 0.0 => 1.0 | ||
% WARNING : Bus 14 : basekv changed 0.0 => 1.0 | ||
% INFO : | ||
% INFO : === Transformer Setting Replacement Notes === | ||
% INFO : | ||
% INFO : === Line Capacity Stat Model Notes === | ||
% WARNING : Missing data for branch flow stat model on line 1-2 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.01938 x=0.05917 | ||
% INFO : Updated Thermal Rating: on line 1-2 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 472 | ||
% WARNING : Missing data for branch flow stat model on line 1-5 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.05403 x=0.22304 | ||
% INFO : Updated Thermal Rating: on line 1-5 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 128 | ||
% WARNING : Missing data for branch flow stat model on line 2-3 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.04699 x=0.19797 | ||
% INFO : Updated Thermal Rating: on line 2-3 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 145 | ||
% WARNING : Missing data for branch flow stat model on line 2-4 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.05811 x=0.17632 | ||
% INFO : Updated Thermal Rating: on line 2-4 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 158 | ||
% WARNING : Missing data for branch flow stat model on line 2-5 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.05695 x=0.17388 | ||
% INFO : Updated Thermal Rating: on line 2-5 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 161 | ||
% WARNING : Missing data for branch flow stat model on line 3-4 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.06701 x=0.17103 | ||
% INFO : Updated Thermal Rating: on line 3-4 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 160 | ||
% WARNING : Missing data for branch flow stat model on line 4-5 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.01335 x=0.04211 | ||
% INFO : Updated Thermal Rating: on line 4-5 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 664 | ||
% WARNING : Missing data for branch flow stat model on line 4-7 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.20912 | ||
% INFO : Updated Thermal Rating: on transformer 4-7 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 141 | ||
% WARNING : Missing data for branch flow stat model on line 4-9 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.55618 | ||
% INFO : Updated Thermal Rating: on transformer 4-9 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 53 | ||
% WARNING : Missing data for branch flow stat model on line 5-6 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.25202 | ||
% INFO : Updated Thermal Rating: on transformer 5-6 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 117 | ||
% WARNING : Missing data for branch flow stat model on line 6-11 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.09498 x=0.1989 | ||
% INFO : Updated Thermal Rating: on line 6-11 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 134 | ||
% WARNING : Missing data for branch flow stat model on line 6-12 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.12291 x=0.25581 | ||
% INFO : Updated Thermal Rating: on line 6-12 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 104 | ||
% WARNING : Missing data for branch flow stat model on line 6-13 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.06615 x=0.13027 | ||
% INFO : Updated Thermal Rating: on line 6-13 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 201 | ||
% WARNING : Missing data for branch flow stat model on line 7-8 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.17615 | ||
% INFO : Updated Thermal Rating: on line 7-8 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 167 | ||
% WARNING : Missing data for branch flow stat model on line 7-9 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.11001 | ||
% INFO : Updated Thermal Rating: on line 7-9 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 267 | ||
% WARNING : Missing data for branch flow stat model on line 9-10 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.03181 x=0.0845 | ||
% INFO : Updated Thermal Rating: on line 9-10 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 325 | ||
% WARNING : Missing data for branch flow stat model on line 9-14 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.12711 x=0.27038 | ||
% INFO : Updated Thermal Rating: on line 9-14 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 99 | ||
% WARNING : Missing data for branch flow stat model on line 10-11 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.08205 x=0.19207 | ||
% INFO : Updated Thermal Rating: on line 10-11 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 141 | ||
% WARNING : Missing data for branch flow stat model on line 12-13 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.22092 x=0.19988 | ||
% INFO : Updated Thermal Rating: on line 12-13 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 99 | ||
% WARNING : Missing data for branch flow stat model on line 13-14 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.17093 x=0.34802 | ||
% INFO : Updated Thermal Rating: on line 13-14 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 76 | ||
% INFO : | ||
% INFO : === Line Capacity Monotonicity Notes === | ||
% INFO : | ||
% INFO : === Voltage Setpoint Replacement Notes === | ||
% INFO : Bus 1 : V=1.06, theta=0.0 -> V=1.0, theta=0.0 | ||
% INFO : Bus 2 : V=1.045, theta=-4.98 -> V=1.0, theta=0.0 | ||
% INFO : Bus 3 : V=1.01, theta=-12.72 -> V=1.0, theta=0.0 | ||
% INFO : Bus 4 : V=1.019, theta=-10.33 -> V=1.0, theta=0.0 | ||
% INFO : Bus 5 : V=1.02, theta=-8.78 -> V=1.0, theta=0.0 | ||
% INFO : Bus 6 : V=1.07, theta=-14.22 -> V=1.0, theta=0.0 | ||
% INFO : Bus 7 : V=1.062, theta=-13.37 -> V=1.0, theta=0.0 | ||
% INFO : Bus 8 : V=1.09, theta=-13.36 -> V=1.0, theta=0.0 | ||
% INFO : Bus 9 : V=1.056, theta=-14.94 -> V=1.0, theta=0.0 | ||
% INFO : Bus 10 : V=1.051, theta=-15.1 -> V=1.0, theta=0.0 | ||
% INFO : Bus 11 : V=1.057, theta=-14.79 -> V=1.0, theta=0.0 | ||
% INFO : Bus 12 : V=1.055, theta=-15.07 -> V=1.0, theta=0.0 | ||
% INFO : Bus 13 : V=1.05, theta=-15.16 -> V=1.0, theta=0.0 | ||
% INFO : Bus 14 : V=1.036, theta=-16.04 -> V=1.0, theta=0.0 | ||
% INFO : | ||
% INFO : === Generator Setpoint Replacement Notes === | ||
% INFO : Gen at bus 1 : Pg=232.4, Qg=-16.9 -> Pg=170.0, Qg=5.0 | ||
% INFO : Gen at bus 1 : Vg=1.06 -> Vg=1.0 | ||
% INFO : Gen at bus 2 : Pg=40.0, Qg=42.4 -> Pg=29.5, Qg=0.0 | ||
% INFO : Gen at bus 2 : Vg=1.045 -> Vg=1.0 | ||
% INFO : Gen at bus 3 : Pg=0.0, Qg=23.4 -> Pg=0.0, Qg=20.0 | ||
% INFO : Gen at bus 3 : Vg=1.01 -> Vg=1.0 | ||
% INFO : Gen at bus 6 : Pg=0.0, Qg=12.2 -> Pg=0.0, Qg=9.0 | ||
% INFO : Gen at bus 6 : Vg=1.07 -> Vg=1.0 | ||
% INFO : Gen at bus 8 : Pg=0.0, Qg=17.4 -> Pg=0.0, Qg=9.0 | ||
% INFO : Gen at bus 8 : Vg=1.09 -> Vg=1.0 | ||
% INFO : | ||
% INFO : === Writing Matpower Case File Notes === |