Skip to content

Commit

Permalink
CHESTER: Add ble tag documentation for CHESTER clime (#102)
Browse files Browse the repository at this point in the history
* CHESTER: Add ble tag documentation for CHESTER clime

Signed-off-by: José Mendes <[email protected]>

* Update chester-clime.md

---------

Signed-off-by: José Mendes <[email protected]>
Co-authored-by: José Mendes <[email protected]>
Co-authored-by: Martin Hub <[email protected]>
  • Loading branch information
3 people authored Sep 6, 2024
1 parent cf4ba41 commit 895c438
Showing 1 changed file with 121 additions and 1 deletion.
122 changes: 121 additions & 1 deletion chester/catalog-applications/chester-clime.md
Original file line number Diff line number Diff line change
Expand Up @@ -274,6 +274,42 @@ Command to set the **report rate** in reports per hour (just for event reports,
app config event-report-rate <1-3600>
```

## CHESTER Clime BLE Tag subsystem

The catalog application **CHESTER Clime Tag** supports up to 8 **Teltonika EYE Sensor** Bluetooth tags that report temperature and humidity. This subsystem can be activated by following command:

```
tag config enabled true
```

After enabling the subsystem, save the configuration in order to restart **CHESTER** and start the subsystem:

```
save config
```

To use these sensors, the device must enroll them first. To enroll a tag, place it in very close proximity to CHESTER, run the following command and wait up to 10 seconds for the device to be discovered.

```
tag config devices enroll
```

To make the enrollment of these devices permanent, save them to the configuration with the previous command.

**Tag configuration:**

The tags can be configured using the [EYE APP](https://wiki.teltonika-gps.com/view/EYE_SENSOR_/_BTSMP1#EYE_App_Configuration).

**Setup tips:**

The working distance between CHESTER and the Teltonika sensors depends on the signal power configuration of the sensor. To test the signal strenght at the distance, run the following command and look at the rssi value:

```
tag config devices read
```

If the signal strength is lower than -85 dbm, consider boosting the signal power to assure reliable communication.

## Firmware

:::danger
Expand Down Expand Up @@ -847,7 +883,7 @@ In each structure with the current configuration, there are six aggregated value
]
}
],
"rtd_thermometers": [
"rtd_thermometers": [
{
"channel": 1,
"measurements": [
Expand Down Expand Up @@ -942,6 +978,90 @@ In each structure with the current configuration, there are six aggregated value
}
]
}
],
"ble_tags": [
{
"addr": "1234567890AB",
"rssi": -81,
"voltage": 3.11,
"humidity": {
"measurements": [
{
"timestamp": 1668857742,
"min": 54.78,
"max": 55.31,
"avg": 55.1,
"mdn": 55.12
},
{
"timestamp": 1668858042,
"min": 55.12,
"max": 56.16,
"avg": 55.55,
"mdn": 55.52
}
]
},
"temperature": {
"measurements": [
{
"timestamp": 1668857742,
"min": 22.18,
"max": 22.25,
"avg": 22.23,
"mdn": 22.25
},
{
"timestamp": 1668858042,
"min": 22.18,
"max": 22.18,
"avg": 22.18,
"mdn": 22.18
}
]
}
},
{
"addr": "BA0987654321",
"rssi": -77,
"voltage": 3.11,
"humidity": {
"measurements": [
{
"timestamp": 1668857742,
"min": 54.78,
"max": 55.31,
"avg": 55.1,
"mdn": 55.12
},
{
"timestamp": 1668858042,
"min": 55.12,
"max": 56.16,
"avg": 55.55,
"mdn": 55.52
}
]
},
"temperature": {
"measurements": [
{
"timestamp": 1668857742,
"min": 22.18,
"max": 22.25,
"avg": 22.23,
"mdn": 22.25
},
{
"timestamp": 1668858042,
"min": 22.18,
"max": 22.18,
"avg": 22.18,
"mdn": 22.18
}
]
}
}
]
}
```

0 comments on commit 895c438