Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Initial deisotoping #5

Draft
wants to merge 4 commits into
base: main
Choose a base branch
from
Draft

Initial deisotoping #5

wants to merge 4 commits into from

Conversation

bittremieux
Copy link
Owner

@bittremieux bittremieux commented Apr 29, 2019

Spectrum deisotoping based on the theoretical isotope intensity ratios by Valkenborg et al. (2008).

First, sequences of peaks at isotopic mass differences are identified. Next, the intensity ratios are compared to the expected theoretical intensity ratios based on the polynomial model by Valkenborg et al. A X² test is used to determine whether the ratios are similar enough.

Deisotoping example

@Valkenborg, a few questions if you don't mind.

  • Could you have a look at the code to see if it correctly applies the procedure that you've described in your paper?
  • Do you have an intuition about the threshold for the X² test? The manuscript says it depends on the data, which makes sense, but a robust default value would be useful. What's an appropriate magnitude for example?
  • This research is more than a decade old by now, would you say that this is still the recommended way to deisotope MS2 spectra?

@bittremieux bittremieux marked this pull request as draft April 1, 2021 00:30
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.

1 participant