Component for esphome to read status from a Junctek KG-F coulometer/battery monitor via UART

License

Notifications You must be signed in to change notification settings

alanv72/esphome-junctek_kgf

 
 

Repository files navigation

esphome-junctek_kgf

Component for esphome to read status from a Junctek KG-F coulometer/battery monitor via UART

Features

Connects to the Junctek KGF series battery monitor via UART (RS-485 adapter needed) and retrieves the following values:

  • Battery Voltage
  • Battery Percent
  • Current Amps
  • Temperature
  • Plus Much more!

Requirements

  • ESPHome

Tested setup

Tested on ESP32 using a RS-485 uart into a Junctek KG110F, but should work on an ESP8266 and any of the KG-F series

Usage

Connect hardware.

The ESP32 needs to be connected via an RS-485 module to the RS-485 on the monitor using a 4cp4 connector.

alanv72 confirmed working with ESP8266 with rs485 that doesn't need flowcontrol ping like max485. Couldn't make work with esp32 or max485 ¯_(ツ)_/¯ Working with a KG160F (600amp) with display connected.

expanded sensors based on tfyoung#14

Thanks to https://github.com/Lukylic!

Update c+ code for newest firmware that has different string for reading measurements and doesn't have power in Watt's. C+ code calcs Watts based on amp * volatage and reports with orginal sensor name.

2024/11/23 - Corrected Total AH calcs.

Sample: Address/ID CRC Volts *.01 Amps *.01 AH Remaining *.001 AH Cumulative *.001 Watthours remaing System runtime Temp Special Function Relay state Current Direction Battery runtime in mins Batt Resistance *01 mOh 5 105 5206 6054 295606 5353 1295308 14069 127 0 0 0 292 5499 5 141 5206 6056 295303 5656 1295308 14087 127 0 0 0 292 5515 5 140 5206 6055 295303 5656 1295308 14087 127 0 0 0 292 5515

Expanded sample with 10min rolling avg battery runtime: expanded_sample.yaml

ESPHOME Config

The applicable config for the device should look something like:

external_components:
  - source: github://alanv72/esphome-junctek_kgf

uart: 
 ######### UART for the Juncteck (1) ######
  - id: kg_uart
    tx_pin: GPIO03
    rx_pin: GPIO01
    baud_rate: 115200
    rx_buffer_size: 384

sensor:
  - platform: junctek_kgf    
    uart_id: kg_uart
    address: 1
    invert_current: false
    voltage:
      name: "junctek1_battery_voltage"
    current:
      name: "junctek1_battery_current"
    battery_level:
      name: "junctek1_battery_level"
    temperature:
      name: "junctek1_temperature"
    ah_battery_level:
      name: "junctek1_ah_battery_level" 
    ah_total_used:
      name: "junctek1_ah_total_used"
    wh_battery_level:
      name: "junctek1_wh_battery_level"
    running_time:
      name: "junctek1_running_time"
    battery_internal_resistor:
      name: "junctek1_battery_internal_resistor" 
    battery_life:
      name: "junctek1_battery_life"
    power:
      name: "junctek1_power"  
    relay_status:
      name: "junctek1_relay_status" 
    direction:   
      name: "junctek1_direction"  
######## Relay set value ##########
    over_voltage_set:   
      name: "junctek1_over_voltage_set"  
    under_voltage_set:
      name: "junctek1_under_voltage_set" 
    positive_overcurrent_set:
      name: "junctek1_positive_overcurrent_set" 
    negative_overcurrent_set:
      name: "junctek1_negative_overcurrent_set" 
    over_power_protection_set:
      name: "junctek1_over_power_protection_set" 
    over_temperature_set:
      name: "junctek1_over_temperature_set" 
    protection_recovery_seconds_set:
      name: "junctek1_protection_recovery_seconds_set" 
    delay_time_set:
      name: "junctek1_delay_time_set" 
    battery_amphour_capacity_set:
      name: "junctek1_battery_amphour_capacity_set" 
    voltage_calibration_set:
      name: "junctek1_voltage_calibration_set" 
    current_calibration_set:
      name: "junctek1_current_calibration_set" 
    temperature_calibration_set:
      name: "junctek1_temperature_calibration_set" 
    reserved_set:
      name: "junctek1_reserved_set" 
    relay_normally_open:
      name: "junctek1_relay_normally_open" 
    current_ratio_set:
      name: "junctek1_current_ratio_set" 

UPDATED!! all sensors added. Address is assumed to be 1 if not provided. (this is configured on the monitor) invert_current: This inverts the reported current, it's recommended to include this option with either true or false (which ever makes the current make more sense for your setup). The default is currently false (and false will match previous behaviour), but may change to true in future updates.

About

Component for esphome to read status from a Junctek KG-F coulometer/battery monitor via UART

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C++ 57.5%
  • Python 42.5%