CurrentSwitch Is a library to use non invasive current probe to use it a a 'working proof'. This skecht use a SCT-013-000. Interface with arduino here and original emonLib library:
*** https://github.com/openenergymonitor/EmonLib ***
Instead of emonLib that read real current, this on only return 'true' if there is 'some current'. This is usefull usefull as workproof and very weightless compare to emonLib.
https://www.dropbox.com/sh/vzn5upzlsvuat84/AADQE0GaEtgEIRmh-AHvIBM9a?dl=0
- Simpler, lighter API
- Add of on rise, on drop and on change function
- Could be use with other analog current sensor ( 0A have to be at center resolution: 512/1024 or 2048/4096)
CurrentSwitch myLoad(reso, IRange, ITreshold);
- Reso: The analog resolution of the ADC, ANALOG_RESO_10 OR ANALOG_RESO_12
- IRange: The range that the current sensor can read in ampere
- ITreshold: The current level of the load
#define SECTOR_FREQUENCY 60
void setup() {
//Monitoring of sensor is done trough an interrupt timer
Timer1.initialize(myLoad.currentSamplingPeriod(SECTOR_FREQUENCY));
Timer1.attachInterrupt(readCurrentISR); // handle monitoring of all CurrentSwitch instance
}
void readCurrentISR()
{
//read all currentSwitch into the ISR
myLoad.read(analogRead(INPUT1));
//other CurrentSwitch.read( [INPUT] );
}
The "currentSamplingPeriod()" will calculate a sampling period of 1 and 2/3 the sector period. Change SECTOR_FREQUENCY to match your country electric distritution: 50 or 60 Hz.
Put into Your ISR all current input you want to monitor.
void loop() {
//use the workProff function to trigger something
if (myLoad.workProof()) { //if working
Serial.println("input working");
}
else if (!myLoad.workProof()) { //if not working
Serial.println("input not working");
}
}
if (myLoad.rised()) {
Serial.println("The load started!");
}
if (myLoad.droped()) {
Serial.println("The load stoped!")
}
if (myLoad.changed() == RISE) {
Serial.println("The load started!");
}
else if (myLoad.changed() == DROP) {
Serial.println("The load stoped!");
}
The front detector only keep the last change until it is checked. If you do not call "rised()" before the load stop, it will return false.
Also, changed use the same status flag that droped and rised so the cannot be use un the same time. if one return non-0, the flag is reset and until another detection, all function will return 0;