Notifications
You must be signed in to change notification settings - Fork 57
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
New DF system YML and options_lookup entries
- Loading branch information
Showing
2 changed files
with
202 additions
and
0 deletions.
There are no files selected for viewing
193 changes: 193 additions & 0 deletions
193
project_national/national_upgrades_HPs_30k_AMY2018_DF.yml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,193 @@ | ||
schema_version: '0.4' | ||
os_version: 3.8.0 | ||
os_sha: f953b6fcaf | ||
buildstock_directory: ../ # Relative to this file or absolute | ||
project_directory: project_national # Relative to buildstock_directory | ||
# output_directory: /projects/heatpump/test_runs/n_500_20240530_2007_v1 | ||
output_directory: /kfs2/projects/heatpump/test_runs/test_amy_30k_full_run_case_12 | ||
# weather_files_url: https://data.nrel.gov/system/files/156/Buildstock_TMY3_FIPS-1678817889.zip | ||
weather_files_path: /kfs2/shared-projects/buildstock/weather/BuildStock_2018_FIPS.zip | ||
|
||
sampler: | ||
type: residential_quota | ||
args: | ||
n_datapoints: 30000 | ||
|
||
workflow_generator: | ||
type: residential_hpxml | ||
version: 2024.07.20 | ||
args: | ||
build_existing_model: | ||
simulation_control_timestep: 15 | ||
simulation_control_run_period_begin_month: 1 | ||
simulation_control_run_period_begin_day_of_month: 1 | ||
simulation_control_run_period_end_month: 12 | ||
simulation_control_run_period_end_day_of_month: 31 | ||
simulation_control_run_period_calendar_year: 2018 | ||
add_component_loads: true | ||
|
||
emissions: | ||
- scenario_name: LRMER_MidCase_15 | ||
type: CO2e | ||
elec_folder: data/emissions/cambium/2022/LRMER_MidCase_15 | ||
|
||
utility_bills: | ||
- scenario_name: Bills | ||
|
||
simulation_output_report: | ||
timeseries_frequency: monthly | ||
include_timeseries_total_consumptions: false | ||
include_timeseries_fuel_consumptions: false | ||
include_timeseries_end_use_consumptions: true | ||
include_timeseries_emissions: false | ||
include_timeseries_emission_fuels: false | ||
include_timeseries_emission_end_uses: false | ||
include_timeseries_hot_water_uses: false | ||
include_timeseries_total_loads: true | ||
include_timeseries_component_loads: false | ||
include_timeseries_unmet_hours: false | ||
include_timeseries_zone_temperatures: false | ||
include_timeseries_airflows: false | ||
include_timeseries_weather: true | ||
include_timeseries_resilience: false | ||
include_monthly_bills: true | ||
|
||
reporting_measures: | ||
- measure_dir_name: QOIReport | ||
|
||
server_directory_cleanup: | ||
retain_schedules_csv: false | ||
|
||
kestrel: | ||
n_jobs: 10 | ||
minutes_per_sim: 5 | ||
account: heatpump | ||
postprocessing: | ||
time: 600 | ||
n_workers: 4 | ||
sampling: | ||
time: 20 | ||
|
||
postprocessing: | ||
keep_individual_timeseries: true | ||
# partition_columns: | ||
# - State | ||
# - County | ||
aws: | ||
region_name: us-west-2 | ||
s3: | ||
bucket: heat-pump-deployment | ||
prefix: test_runs | ||
athena: | ||
glue_service_role: service-role/AWSGlueServiceRole-default | ||
database_name: heatpumpdeployment | ||
max_crawling_time: 1200 | ||
|
||
baseline: | ||
n_buildings_represented: 139647020 # American Community Survey 2021 5-year, B25001, does not include territories ( 138765649 without AK and HI ) | ||
|
||
upgrades: | ||
|
||
- upgrade_name: Case 13a - New Dual-Fuel System - 20F backup lockout | ||
|
||
package_apply_logic: &remove_non_fossil_non_elec_fuels | ||
- not: Heating Fuel|Wood | ||
- not: Heating Fuel|Other Fuel | ||
- not: Heating Fuel|None | ||
|
||
options: | ||
- &hvac_heating_efficiency_ashp_case_13a_ng | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13a NG, 20F | ||
apply_logic: &ducted_ASHP_apply_logic_ng | ||
- HVAC Has Ducts|Yes | ||
- Heating Fuel|Natural Gas | ||
costs: &dummy_cost_values | ||
- value: 999 # dummy value | ||
multiplier: Size, Heating System Primary (kBtu/h) | ||
lifetime: &dummy_lifetime_value 30 | ||
|
||
- &hvac_heating_efficiency_ashp_case_13a_fo | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13a FO, 20F | ||
apply_logic: &ducted_ASHP_apply_logic_fo | ||
- HVAC Has Ducts|Yes | ||
- Heating Fuel|Fuel Oil | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- &hvac_heating_efficiency_ashp_case_13a_propane | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13a Propane, 20F | ||
apply_logic: &ducted_ASHP_apply_logic_propane | ||
- HVAC Has Ducts|Yes | ||
- Heating Fuel|Propane | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- &hvac_cooling_efficiency_ducted_heat_pump_fossil | ||
option: HVAC Cooling Efficiency|Ducted Heat Pump | ||
apply_logic: &ducted_ASHP_apply_logic_fossil | ||
- HVAC Has Ducts|Yes | ||
- or: | ||
- Heating Fuel|Natural Gas | ||
- Heating Fuel|Fuel Oil | ||
- Heating Fuel|Propane | ||
- &hvac_distribution_use_autosizing_limits_and_maintain_duct_system_curve_fossil | ||
option: HVAC Distribution|Use Autosizing Limits and Maintain Duct System Curve | ||
apply_logic: *ducted_ASHP_apply_logic_fossil | ||
- &hvac_performance_data_ashp_case_13 | ||
option: HVAC Detailed Performance Data|High COP Part Load Ducted | ||
apply_logic: *ducted_ASHP_apply_logic_fossil | ||
|
||
- upgrade_name: Case 13b - New Dual-Fuel System - 30F backup lockout | ||
|
||
package_apply_logic: *remove_non_fossil_non_elec_fuels | ||
|
||
options: | ||
- &hvac_heating_efficiency_ashp_case_13b_ng | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13b NG, 30F | ||
apply_logic: *ducted_ASHP_apply_logic_ng | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- &hvac_heating_efficiency_ashp_case_13b_fo | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13b FO, 20F | ||
apply_logic: *ducted_ASHP_apply_logic_fo | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- &hvac_heating_efficiency_ashp_case_13b_propane | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13b Propane, 20F | ||
apply_logic: *ducted_ASHP_apply_logic_propane | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- *hvac_cooling_efficiency_ducted_heat_pump_fossil | ||
- *hvac_distribution_use_autosizing_limits_and_maintain_duct_system_curve_fossil | ||
- *hvac_performance_data_ashp_case_13 | ||
|
||
- upgrade_name: Case 13b - New Dual-Fuel System - 30F backup lockout | ||
|
||
package_apply_logic: *remove_non_fossil_non_elec_fuels | ||
|
||
options: | ||
- &hvac_heating_efficiency_ashp_case_13c_ng | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13c NG, 30F | ||
apply_logic: *ducted_ASHP_apply_logic_ng | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- &hvac_heating_efficiency_ashp_case_13c_fo | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13c FO, 20F | ||
apply_logic: *ducted_ASHP_apply_logic_fo | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- &hvac_heating_efficiency_ashp_case_13c_propane | ||
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13c Propane, 20F | ||
apply_logic: *ducted_ASHP_apply_logic_propane | ||
costs: *dummy_cost_values | ||
lifetime: *dummy_lifetime_value | ||
|
||
- *hvac_cooling_efficiency_ducted_heat_pump_fossil | ||
- *hvac_distribution_use_autosizing_limits_and_maintain_duct_system_curve_fossil | ||
- *hvac_performance_data_ashp_case_13 | ||
|
Oops, something went wrong.