@@ -0,0 +1,193 @@
schema_version: '0.4'
os_version: 3.8.0
os_sha: f953b6fcaf
buildstock_directory: ../ # Relative to this file or absolute
project_directory: project_national # Relative to buildstock_directory
# output_directory: /projects/heatpump/test_runs/n_500_20240530_2007_v1
output_directory: /kfs2/projects/heatpump/test_runs/test_amy_30k_full_run_case_12
# weather_files_url: https://data.nrel.gov/system/files/156/Buildstock_TMY3_FIPS-1678817889.zip
weather_files_path: /kfs2/shared-projects/buildstock/weather/BuildStock_2018_FIPS.zip

sampler:
type: residential_quota
args:
n_datapoints: 30000

workflow_generator:
type: residential_hpxml
version: 2024.07.20
args:
build_existing_model:
simulation_control_timestep: 15
simulation_control_run_period_begin_month: 1
simulation_control_run_period_begin_day_of_month: 1
simulation_control_run_period_end_month: 12
simulation_control_run_period_end_day_of_month: 31
simulation_control_run_period_calendar_year: 2018
add_component_loads: true

emissions:
- scenario_name: LRMER_MidCase_15
type: CO2e
elec_folder: data/emissions/cambium/2022/LRMER_MidCase_15

utility_bills:
- scenario_name: Bills

simulation_output_report:
timeseries_frequency: monthly
include_timeseries_total_consumptions: false
include_timeseries_fuel_consumptions: false
include_timeseries_end_use_consumptions: true
include_timeseries_emissions: false
include_timeseries_emission_fuels: false
include_timeseries_emission_end_uses: false
include_timeseries_hot_water_uses: false
include_timeseries_total_loads: true
include_timeseries_component_loads: false
include_timeseries_unmet_hours: false
include_timeseries_zone_temperatures: false
include_timeseries_airflows: false
include_timeseries_weather: true
include_timeseries_resilience: false
include_monthly_bills: true

reporting_measures:
- measure_dir_name: QOIReport

server_directory_cleanup:
retain_schedules_csv: false

kestrel:
n_jobs: 10
minutes_per_sim: 5
account: heatpump
postprocessing:
time: 600
n_workers: 4
sampling:
time: 20

postprocessing:
keep_individual_timeseries: true
# partition_columns:
# - State
# - County
aws:
region_name: us-west-2
s3:
bucket: heat-pump-deployment
prefix: test_runs
athena:
glue_service_role: service-role/AWSGlueServiceRole-default
database_name: heatpumpdeployment
max_crawling_time: 1200

baseline:
n_buildings_represented: 139647020 # American Community Survey 2021 5-year, B25001, does not include territories ( 138765649 without AK and HI )

upgrades:

- upgrade_name: Case 13a - New Dual-Fuel System - 20F backup lockout

package_apply_logic: &remove_non_fossil_non_elec_fuels
- not: Heating Fuel|Wood
- not: Heating Fuel|Other Fuel
- not: Heating Fuel|None

options:
- &hvac_heating_efficiency_ashp_case_13a_ng
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13a NG, 20F
apply_logic: &ducted_ASHP_apply_logic_ng
- HVAC Has Ducts|Yes
- Heating Fuel|Natural Gas
costs: &dummy_cost_values
- value: 999 # dummy value
multiplier: Size, Heating System Primary (kBtu/h)
lifetime: &dummy_lifetime_value 30

- &hvac_heating_efficiency_ashp_case_13a_fo
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13a FO, 20F
apply_logic: &ducted_ASHP_apply_logic_fo
- HVAC Has Ducts|Yes
- Heating Fuel|Fuel Oil
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- &hvac_heating_efficiency_ashp_case_13a_propane
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13a Propane, 20F
apply_logic: &ducted_ASHP_apply_logic_propane
- HVAC Has Ducts|Yes
- Heating Fuel|Propane
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- &hvac_cooling_efficiency_ducted_heat_pump_fossil
option: HVAC Cooling Efficiency|Ducted Heat Pump
apply_logic: &ducted_ASHP_apply_logic_fossil
- HVAC Has Ducts|Yes
- or:
- Heating Fuel|Natural Gas
- Heating Fuel|Fuel Oil
- Heating Fuel|Propane
- &hvac_distribution_use_autosizing_limits_and_maintain_duct_system_curve_fossil
option: HVAC Distribution|Use Autosizing Limits and Maintain Duct System Curve
apply_logic: *ducted_ASHP_apply_logic_fossil
- &hvac_performance_data_ashp_case_13
option: HVAC Detailed Performance Data|High COP Part Load Ducted
apply_logic: *ducted_ASHP_apply_logic_fossil

- upgrade_name: Case 13b - New Dual-Fuel System - 30F backup lockout

package_apply_logic: *remove_non_fossil_non_elec_fuels

options:
- &hvac_heating_efficiency_ashp_case_13b_ng
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13b NG, 30F
apply_logic: *ducted_ASHP_apply_logic_ng
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- &hvac_heating_efficiency_ashp_case_13b_fo
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13b FO, 20F
apply_logic: *ducted_ASHP_apply_logic_fo
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- &hvac_heating_efficiency_ashp_case_13b_propane
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13b Propane, 20F
apply_logic: *ducted_ASHP_apply_logic_propane
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- *hvac_cooling_efficiency_ducted_heat_pump_fossil
- *hvac_distribution_use_autosizing_limits_and_maintain_duct_system_curve_fossil
- *hvac_performance_data_ashp_case_13

- upgrade_name: Case 13b - New Dual-Fuel System - 30F backup lockout

package_apply_logic: *remove_non_fossil_non_elec_fuels

options:
- &hvac_heating_efficiency_ashp_case_13c_ng
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13c NG, 30F
apply_logic: *ducted_ASHP_apply_logic_ng
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- &hvac_heating_efficiency_ashp_case_13c_fo
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13c FO, 20F
apply_logic: *ducted_ASHP_apply_logic_fo
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- &hvac_heating_efficiency_ashp_case_13c_propane
option: HVAC Heating Efficiency|Dual-Fuel ASHP, SEER2 17.3, 8.7 HSPF2, Case 13c Propane, 20F
apply_logic: *ducted_ASHP_apply_logic_propane
costs: *dummy_cost_values
lifetime: *dummy_lifetime_value

- *hvac_cooling_efficiency_ducted_heat_pump_fossil
- *hvac_distribution_use_autosizing_limits_and_maintain_duct_system_curve_fossil
- *hvac_performance_data_ashp_case_13