deephog commented Feb 22, 2023

I realize that even with the newest (not yet released) OAK-D Pro W PoE, there isn't a general genlock connector. But you mentioned about being able to do hardware triggered synchronization between devices, is there a tutorial for that? or is there a way to make genlock work with oak-d? Thanks!

@Erol444
Copy link
Member

Erol444 commented Feb 26, 2023

Hi @deephog !
For HW syncing, please see docs here. BNC/genlock syncing isn't supported directly, but one could create a converter from BNC to M8 connector, so it would trigger FSYNC line. This is also on our roadmap, but there's no ETA yet. Thoughts?
Thanks, Erik

@Erol444 Erol444 transferred this issue from luxonis/depthai-core Mar 16, 2023
@Erol444 Erol444 assigned Luxonis-David and unassigned Erol444 Mar 16, 2023
@Luxonis-David
Copy link
Contributor

Opened new relevant issue #385

@Erol444 Erol444 closed this as completed Mar 30, 2023