Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Regional prompt works ONLY with Euler+normal! With any other sampler, the result is blurry or mess #58

Open
PsypmP opened this issue Jan 18, 2024 · 1 comment

Comments

@PsypmP
Copy link

PsypmP commented Jan 18, 2024

Euler
image

Ddim+ddim uni = mess
image

dpmpp_2m_sde+karras
Ksampler vs RegionalKsampler
image

@ltdrdata
Copy link
Owner

ltdrdata commented Jan 19, 2024

The current implementation is based on the chaining of KSampler Advanced, which is why it is the case.

Some samplers introduce new noise intermittently during the sampling process, and when trying to separate and work on it through KSampler Advanced, it doesn't handle it properly.

To handle this appropriately, modifications need to be made deeper within the Sampler. However, this is currently restricted to the core, so I am in the process of contemplating a solution.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment