You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When adding a Calibration Bar via Analyze->Tools and setting a low zoom level of, e.g., 0.1 (which is often necessary when adding calib. bars to very zoom in content), the calibration bar is not drawn correctly any more. As shown in the image below, the colored stripes protrude through the black border:
The text was updated successfully, but these errors were encountered:
This will create a misrendered calibration bar in the top right of the zoomed part of the image. The misrendering happens when low zoom factors are set in the calibration bar tool (such as the 0.3 here), which is needed for high zoom levels.
ImageJ v1.54e
Windows 10 x64
Java 11.0.14.1.
Description
When adding a Calibration Bar via Analyze->Tools and setting a low zoom level of, e.g., 0.1 (which is often necessary when adding calib. bars to very zoom in content), the calibration bar is not drawn correctly any more. As shown in the image below, the colored stripes protrude through the black border:
The text was updated successfully, but these errors were encountered: