The subchannel solver currently neglects frictional pressure drop along the main flow direction. This can be added to obtain a more realistic solution. If desired, we can iterate on the mass flowrate in each channel until the pressure drop over each channel is approximately constant, or we can permit a pressure distribution on the inlet for simplicity.
The text was updated successfully, but these errors were encountered:
aprilnovak
changed the title
Frictional pressure drop
Add frictional pressure drop to subchannel solver
Jul 12, 2019
The subchannel solver currently neglects frictional pressure drop along the main flow direction. This can be added to obtain a more realistic solution. If desired, we can iterate on the mass flowrate in each channel until the pressure drop over each channel is approximately constant, or we can permit a pressure distribution on the inlet for simplicity.