Packet Format

All packets are recieved as raw ethernet frames with a protocol set as type 0x88b5 which wireshark identifies as 'Local Experimental Ethertype 1'

Following the ethernet header, various types of data packets can be seen from coming from the device.

Header

All packets start with a 30 byte long header formatted as below

Start Address Size (Bytes) Description Contents
0x00 4 Packet Header? CB DA E9 F8
0x04 16 Unknown (Padding?) 0x00
0x14 1 Unknown 0x01
0x15 3 Unknown (Padding) 0x00
0x18 1 Message Length Various (See Below)
0x19 1 Device Type ? Always 0x53
0x1A 2 Message Type 1 ?
0x1B 2 Message Type 2 ?

Various Types of packets have been observed so far.

Packet Types

Packet Len Data Length (Bytes) Contents Transmit Rate (Seconds) Notes
0x1F 55 Eddi Data (Packet Type 1) 24
0x20 56 Eddi Data (Packet Type 2) 12
0x2B 67 Eddi Data (Packet Type 3) 12 data not consistant
0x2C 68 ?? 12
0x2D 69 ?? 12
0x22 58 CT Readings? 2
0x27 63 Unknown 4
0x36 78 Unknown 2
0x37 79 Unknown tbc
0x38 80 Unknown tbc
0x39 81 Unknown tbc
0x3a 82 Unknown tbc

The following Packets have been decoded (or partially decoded) so far

0x1F - Eddi Data (Packet Type 1)

Transmitted Approx Every 12 seconds

Start Address Size (Bytes) Data Type Description Post Processing
0x1E 4 int32 Serial Number N/A
0x22 2 int16 Grid Frequency Divide by 100
0x2C 2 int16 Diverted kWh / 100
0x32 2 int16 Voltage Divide by 10

0x20 - Eddi Data (Packet Type 2)

Transmitted Approx Every 24 seconds

Start Address Size (Bytes) Data Type Description Post Processing
0x1E 4 int32 Serial Number N/A
0x22 2 int16 Grid Frequency Divide by 100
0x2C 2 int16 Diverted kWh / 100
0x24 2 bool Status Bit?
0x26 2 int16 Max Heater Power (*1)
0x34 2 int16 Divert Power / 100
0x36 2 int16 Divert Current? / 100
0x2E.0 1 bool Boosting N/A
0x2F.7 1 bool Heater 1 Active N/A
0x2F.6 1 bool Heater 2 Active N/A
0x2F.5 1 bool unknown N/A
0x2F.4 1 bool unknown N/A
0x2F.3 1 bool unknown N/A
0x2F.2 1 bool unknown N/A
0x2F.1 1 bool unknown N/A
0x2F.0 1 bool unknown N/A
0x25.7 1 bool Stopped Mode N/A
  1. Appears to be the maximum heater power that is connected to the active channel. For example, if you had a 3kW heater then this would read 3000. Sits at maximum rated power (3600) when nothing is connected or channel is off.

0x2B - Eddi Data (Packet Type 3)

Transmitted approx ever 12 seconds. Occasionally sends odd vales for generation & grid power

Start Address Size (Bytes) Data Type Description Post Processing
0x1E 4 int32 Serial Number N/A
0x22 2 int16 Frequency Divide by 100
0x2C 2 int16 Diverted kwH Divide by 100
0x3C 2 int16 Generation Power
0x34 2 int16 Grid Power

0x22 - CT Readings?

Transmitted Approx ever 2 seconds

Start Address Size (Bytes) Data Type Description Post Processing
0x1E 2 int16 Grid Power N/A
0x22 2 int16 Generation Power N/A
0x32 2 int16 Diverting Power N/A
0x2E 4 int32 Serial Number N/A

0x27 - Unknown

Transmitted approx every 4 seconds

Start Address Size (Bytes) Data Type Description Post Processing
0x1E 4 int32 Serial Number N/A
0x22 2 int16 Grid Frequency Divide by 100
0x2C 2 int16 Diverted kWh / 100
0x36 2 int16 Firmware Version (But appears to occasionally go blank)
0x38 2 int16 Firmware Version2(But appears to occasionally go blank)
0x3A 2 int16 Unknown
0x3D 2 int16 Unknown. Seems to track diverter power but not exactly

0x36 - Unknown

Transmitted approx every 2 seconds Occassionally drops all readings to zero.

Start Address Size (Bytes) Data Type Description Post Processing
0x4A 4 int32 Serial Number N/A
0x3A 2 int16 Frequency (Seems to update faster than 0x1F)
0x3C 2 int16 Possibly Heatsink Temperature?
0x38 2 int16 Voltage (Seems to update faster than 0x1F)

0x37 - Unknown

Start Address Size (Bytes) Data Type Description Post Processing
0x1E 4 int32 Serial Number N/A