Describe the bug
When using an Eastron SDM630 Modbus V2 as EVMeter (probably the same when you would be using it as a MainsMet), you get a very precize (lots of digits behind the comma) power reading. This appears not to be rounded up to a reasonable amount of digits behind the comma, leading to an unreadable value on the display.
Upload your config
{"version":"v3.7.1","serialnr":xxxx,"mode":"SMART","mode_id":3,"car_connected":false,"wifi":{"status":"WL_CONNECTED","ssid":"HKHQ Home","rssi":-35,"bssid":"BA:FB:E4:C1:E4:54"},"evse":{"temp":29,"temp_max":65,"connected":false,"access":true,"mode":1,"loadbl":0,"pwm":1024,"custombutton":false,"solar_stop_timer":0,"state":"Ready to Charge","state_id":0,"error":"None","error_id":0,"rfid":"Not Installed"},"settings":{"charge_current":0,"override_current":0,"current_min":6,"current_max":16,"current_main":25,"current_max_circuit":16,"current_max_sum_mains":0,"max_sum_mains_time":0,"solar_max_import":0,"solar_start_current":6,"solar_stop_time":15,"enable_C2":"Auto","mains_meter":"Sensorbox","starttime":0,"stoptime":0,"repeat":0},"mqtt":{"host":"","port":1883,"topic_prefix":"SmartEVSE-7556","username":"","password_set":false,"status":"Disconnected"},"ocpp":{"mode":"Disabled","backend_url":"","cb_id":"","auth_key":"","auto_auth":"Disabled","auto_auth_idtag":"","status":"Disconnected"},"home_battery":{"current":0,"last_update":0},"ev_meter":{"description":"InvEastrn","address":16,"import_active_power":0,"total_kwh":28.79999924,"charged_kwh":0,"currents":{"TOTAL":0,"L1":0,"L2":0,"L3":0},"import_active_energy":28.79999924,"export_active_energy":0},"mains_meter":{"import_active_energy":0,"export_active_energy":0},"phase_currents":{"TOTAL":12,"L1":2,"L2":19,"L3":-9,"last_data_update":1730124410,"original_data":{"TOTAL":12,"L1":2,"L2":19,"L3":-9}},"backlight":{"timer":0,"status":"OFF"},"color":{"off":{"R":0,"G":0,"B":0},"normal":{"R":0,"G":255,"B":0},"smart":{"R":0,"G":255,"B":0},"solar":{"R":255,"G":170,"B":0},"custom":{"R":0,"G":0,"B":255}}}
Upload a debug log
D) (Timer100ms)(C0) ModbusRequest 20: Request EVMeter Current Measurement Node 0
(V) (ModbusSend8)(C0) Sent packet address: 0x10, function: 0x04, reg: 0x0006, token:0x10040006, data: 0x000c.
(V) (ModbusDecode)(C1) Received packet (27 bytes) 10 04 18 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(V) (ModbusDecode)(C1) valid Modbus packet: Address 0x10 Function 0x04 Register 0x0006 Response
(V) (CalcBalancedCurrent)(C0) Checkpoint 1 Isetbalanced=-6.5 A Imeasured=13.2 A MaxCircuit=16 Imeasured_EV=0.0 A, Battery Current = 0.0 A, mode=2.
(V) (CalcBalancedCurrent)(C0) phaseLastUpdate=1730102866.
(V) (CalcBalancedCurrent)(C0) Checkpoint 2 Isetbalanced=0.0 A, Idifference=11.8, mod=0.
(V) (CalcBalancedCurrent)(C0) Checkpoint 3 Isetbalanced=-6.3 A, IsumImport=12.7, Isum=12.7, ImportCurrent=0.
(V) (CalcBalancedCurrent)(C0) Checkpoint 4 Isetbalanced=-6.3 A.
(D) (CalcBalancedCurrent)(C0) Checkpoint c: Resetting SolarStopTimer, MaxSumMainsTimer, IsetBalanced=-6.3A, saveActiveEVSE=0.
(V) (CalcBalancedCurrent)(C0) Checkpoint 5 Isetbalanced=-6.3 A.
(I) (printStatus)(C0) STATE: A Error: 0 StartCurrent: -6 ChargeDelay: 0 SolarStopTimer: 0 NoCurrent: 0 Imeasured: 13.2 A IsetBalanced: -6.3 A, MainsMeter.Timeout=11, EVMeter.Timeout=64.
(I) (printStatus)(C0) L1: 13.2 A L2: -0.2 A L3: -0.3 A Isum: 12.7 A
To Reproduce
Use SDM630 Modbus V2 as EVmeter
Look at the display
Expected behavior
A readable value is shown
Screenshots
The text was updated successfully, but these errors were encountered:
Describe the bug
When using an Eastron SDM630 Modbus V2 as EVMeter (probably the same when you would be using it as a MainsMet), you get a very precize (lots of digits behind the comma) power reading. This appears not to be rounded up to a reasonable amount of digits behind the comma, leading to an unreadable value on the display.
Upload your config
{"version":"v3.7.1","serialnr":xxxx,"mode":"SMART","mode_id":3,"car_connected":false,"wifi":{"status":"WL_CONNECTED","ssid":"HKHQ Home","rssi":-35,"bssid":"BA:FB:E4:C1:E4:54"},"evse":{"temp":29,"temp_max":65,"connected":false,"access":true,"mode":1,"loadbl":0,"pwm":1024,"custombutton":false,"solar_stop_timer":0,"state":"Ready to Charge","state_id":0,"error":"None","error_id":0,"rfid":"Not Installed"},"settings":{"charge_current":0,"override_current":0,"current_min":6,"current_max":16,"current_main":25,"current_max_circuit":16,"current_max_sum_mains":0,"max_sum_mains_time":0,"solar_max_import":0,"solar_start_current":6,"solar_stop_time":15,"enable_C2":"Auto","mains_meter":"Sensorbox","starttime":0,"stoptime":0,"repeat":0},"mqtt":{"host":"","port":1883,"topic_prefix":"SmartEVSE-7556","username":"","password_set":false,"status":"Disconnected"},"ocpp":{"mode":"Disabled","backend_url":"","cb_id":"","auth_key":"","auto_auth":"Disabled","auto_auth_idtag":"","status":"Disconnected"},"home_battery":{"current":0,"last_update":0},"ev_meter":{"description":"InvEastrn","address":16,"import_active_power":0,"total_kwh":28.79999924,"charged_kwh":0,"currents":{"TOTAL":0,"L1":0,"L2":0,"L3":0},"import_active_energy":28.79999924,"export_active_energy":0},"mains_meter":{"import_active_energy":0,"export_active_energy":0},"phase_currents":{"TOTAL":12,"L1":2,"L2":19,"L3":-9,"last_data_update":1730124410,"original_data":{"TOTAL":12,"L1":2,"L2":19,"L3":-9}},"backlight":{"timer":0,"status":"OFF"},"color":{"off":{"R":0,"G":0,"B":0},"normal":{"R":0,"G":255,"B":0},"smart":{"R":0,"G":255,"B":0},"solar":{"R":255,"G":170,"B":0},"custom":{"R":0,"G":0,"B":255}}}
Upload a debug log
D) (Timer100ms)(C0) ModbusRequest 20: Request EVMeter Current Measurement Node 0
(V) (ModbusSend8)(C0) Sent packet address: 0x10, function: 0x04, reg: 0x0006, token:0x10040006, data: 0x000c.
(V) (ModbusDecode)(C1) Received packet (27 bytes) 10 04 18 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(V) (ModbusDecode)(C1) valid Modbus packet: Address 0x10 Function 0x04 Register 0x0006 Response
(V) (CalcBalancedCurrent)(C0) Checkpoint 1 Isetbalanced=-6.5 A Imeasured=13.2 A MaxCircuit=16 Imeasured_EV=0.0 A, Battery Current = 0.0 A, mode=2.
(V) (CalcBalancedCurrent)(C0) phaseLastUpdate=1730102866.
(V) (CalcBalancedCurrent)(C0) Checkpoint 2 Isetbalanced=0.0 A, Idifference=11.8, mod=0.
(V) (CalcBalancedCurrent)(C0) Checkpoint 3 Isetbalanced=-6.3 A, IsumImport=12.7, Isum=12.7, ImportCurrent=0.
(V) (CalcBalancedCurrent)(C0) Checkpoint 4 Isetbalanced=-6.3 A.
(D) (CalcBalancedCurrent)(C0) Checkpoint c: Resetting SolarStopTimer, MaxSumMainsTimer, IsetBalanced=-6.3A, saveActiveEVSE=0.
(V) (CalcBalancedCurrent)(C0) Checkpoint 5 Isetbalanced=-6.3 A.
(I) (printStatus)(C0) STATE: A Error: 0 StartCurrent: -6 ChargeDelay: 0 SolarStopTimer: 0 NoCurrent: 0 Imeasured: 13.2 A IsetBalanced: -6.3 A, MainsMeter.Timeout=11, EVMeter.Timeout=64.
(I) (printStatus)(C0) L1: 13.2 A L2: -0.2 A L3: -0.3 A Isum: 12.7 A
To Reproduce
Use SDM630 Modbus V2 as EVmeter
Look at the display
Expected behavior
A readable value is shown
Screenshots
The text was updated successfully, but these errors were encountered: