Notifications
You must be signed in to change notification settings - Fork 7
/
tristar_monitoring_
executable file
·114 lines (102 loc) · 3.67 KB
/
tristar_monitoring_
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
#!/usr/bin/env python
# Based on Morningstar documentation here
# http://www.morningstarcorp.com/wp-content/uploads/2014/02/TSMPPT.APP_.Modbus.EN_.10.2.pdf
# and heavily modified version of the script here
# http://www.fieldlines.com/index.php?topic=147639.0
import sys
import re
import time
counter = 0
script = sys.argv[0]
host = re.sub(r".*tristar_monitoring_",'',script)
if len(sys.argv) == 2:
if sys.argv[1] == "config":
print "host_name %s" % host
print "graph_category power"
print "graph_title Solar Charge Controller Info"
print "graph_vlabel A bit of all (V, A, C)"
print "vPanel.label panel potential (V)"
print "vPanel.max 80"
print "vBattTerm.label battery potential at terminals (V)"
print "vBattTerm.max 32"
print "vBattTerm.warning 25:32"
print "vBattTerm.critical 24:33"
print "vBattSense.label battery potential sensing (V)"
print "vBattSense.max 32"
print "hsTemp.label heat sink temperature (C)"
print "hsTemp.max 120"
print "hsTemp.warning :60"
print "hsTemp.critical :80"
print "battTemp.label battery temperature (C)"
print "battTemp.max 120"
print "battTemp.warning :80"
print "battTemp.critical :100"
print "aPanel.label panel current (A)"
print "aPanel.max 20"
# print "aPanel.warning :15"
# print "aPanel.critical :19"
print "aBatt.label battery current (A)"
print "aBatt.max 20"
# print "aBatt.warning :15"
# print "aBatt.critical :19"
exit(0)
# import the server implementation
from pymodbus.client.sync import ModbusTcpClient as ModbusClient
# configure the client logging
import logging
logging.basicConfig()
log = logging.getLogger('./modbus.error')
log.setLevel(logging.ERROR)
client = ModbusClient(host,502)
client.connect()
# Define the State list
state = ['Start', 'Night Check', 'Disconnected', 'Night', 'Fault!', 'MPPT', 'Absorption', 'FloatCharge', 'Equalizing', 'Slave']
# read registers. Start at 0 for convenience
rr = client.read_holding_registers(0,80,unit=1)
# for all indexes, subtract 1 from what's in the manual
V_PU_hi = rr.registers[0]
V_PU_lo = rr.registers[1]
I_PU_hi = rr.registers[2]
I_PU_lo = rr.registers[3]
V_PU = float(V_PU_hi) + float(V_PU_lo)
I_PU = float(I_PU_hi) + float(I_PU_lo)
v_scale = V_PU * 2**(-15)
i_scale = I_PU * 2**(-15)
p_scale = V_PU * I_PU * 2**(-17)
# battery sense voltage, filtered
battsV = rr.registers[24] * v_scale
battsSensedV = rr.registers[26] * v_scale
battsI = rr.registers[28] * i_scale
arrayV = rr.registers[27] * v_scale
arrayI = rr.registers[29] * i_scale
statenum = rr.registers[50]
hsTemp = rr.registers[35]
rtsTemp = rr.registers[36]
outPower = rr.registers[58] * p_scale
inPower = rr.registers[59] * p_scale
minVb_daily = rr.registers[64] * v_scale
maxVb_daily = rr.registers[65] * v_scale
minTb_daily = rr.registers[71]
maxTb_daily = rr.registers[72]
dipswitches = bin(rr.registers[48])[::-1][:-2].zfill(8)
led_state = rr.registers
print "vBattTerm.value %.2f" % battsV
print "vBattSense.value %.2f" % battsSensedV
print "aBatt.value %.2f" % battsI
#print "battery watts: %.2f" % (battsV*battsI)
print "vPanel.value %.2f" % arrayV
print "aPanel.value %.2f" % arrayI
#print "array watts: %.2f" % (arrayV*arrayI)
print "hsTemp.value %.2f" % hsTemp
print "battTemp.value %.2f" % rtsTemp
#print "state: %s" % state[statenum]
#print "out power: %0.2f" % outPower
#print "in Power: %0.2f" % inPower
#print "min Vb daily: %0.2f" % minVb_daily
#print "max Vb daily: %0.2f" % maxVb_daily
#print "min Tb daily: %0.2f" % minTb_daily
#print "max Tb daily: %0.2f" % maxTb_daily
#print "dipswitches: %s" % dipswitches
#print "dipswitches: 12345678"
#print ""
client.close()