Tolerance values in strongly coupled systems in SSP are ignored #1328

Open
rruusu opened this issue Oct 30, 2024 · 1 comment
Open

Tolerance values in strongly coupled systems in SSP are ignored #1328

rruusu opened this issue Oct 30, 2024 · 1 comment

Comments

@rruusu
Copy link

rruusu commented Oct 30, 2024

Description

Tolerance values provided in the oms:VariableStepSolver annotation elements in SSP are entirely ignored.

The assumed expected behavior is that unless a tolerance value is provided on the command line, the solver for a strongly coupled system uses the tolerance values that are provided in the SSP annotation elements.

However, unless a command line option is provided, both the absolute and relative tolerance values are overwritten with the default value of 1e-4, instead of using the values from the SystemStructure.ssd document.

Version and OS

  • Version: OMSimulator v2.1.2.post5-gce342b6-mingw-notlm-debug
  • OS: Not relevant
@rruusu
Copy link
Author

rruusu commented Oct 30, 2024

I will push a fix to this to my fork shortly.