You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Emby docker image fails every night, and unable to start unless reboot the dockerd
before it went down, logs mentioned about -- s6-svscanctl: fatal: unable to control /var/run/s6/services: supervisor not listening
Info App: Starting entry point Emby.LiveTV.EntryPoint
Info LiveTV: Loading live tv data from /config/data/livetv/timers
Info App: Entry point completed: Emby.LiveTV.EntryPoint. Duration: 0.0081811 seconds
Info App: Starting entry point Emby.LiveTV.RecordingNotifier
Info App: Entry point completed: Emby.LiveTV.RecordingNotifier. Duration: 0.0064317 seconds
Info App: Starting entry point Emby.ActivityLog.ActivityLogEntryPoint
Info App: Entry point completed: Emby.ActivityLog.ActivityLogEntryPoint. Duration: 0.0096611 seconds
Info App: Starting entry point Emby.Server.MediaEncoding.Api.EncodingManagerEntryPoint
Info LibraryMonitor: Watching directory with new FileSystemWatcher for /media/Documentary for item 5122
Info App: Entry point completed: Emby.Server.MediaEncoding.Api.EncodingManagerEntryPoint. Duration: 0.0233859 seconds
Info App: Starting entry point Emby.Notifications.NotificationManagerEntryPoint
Info Notifications: Registering event nofitier Emby Server User Notifications
Info App: Entry point completed: Emby.Notifications.NotificationManagerEntryPoint. Duration: 0.0399851 seconds
Info App: Starting entry point Emby.Server.Sync.SyncNotificationEntryPoint
Info App: Entry point completed: Emby.Server.Sync.SyncNotificationEntryPoint. Duration: 0.0053606 seconds
Info App: Starting entry point EmbyServer.Windows.LoopUtilEntryPoint
Info App: Entry point completed: EmbyServer.Windows.LoopUtilEntryPoint. Duration: 0.0003221 seconds
Info App: All entry points have started
s6-svscanctl: fatal: unable to control /var/run/s6/services: supervisor not listening
[cont-finish.d] executing container finish scripts...
[cont-finish.d] done.
[s6-finish] waiting for services.
[s6-finish] sending all processes the TERM signal.
[s6-finish] sending all processes the KILL signal and exiting.
Any ideas would be appreciate..
The text was updated successfully, but these errors were encountered:
Emby docker image fails every night, and unable to start unless reboot the dockerd
before it went down, logs mentioned about -- s6-svscanctl: fatal: unable to control /var/run/s6/services: supervisor not listening
Info App: Starting entry point Emby.LiveTV.EntryPoint
Info LiveTV: Loading live tv data from /config/data/livetv/timers
Info App: Entry point completed: Emby.LiveTV.EntryPoint. Duration: 0.0081811 seconds
Info App: Starting entry point Emby.LiveTV.RecordingNotifier
Info App: Entry point completed: Emby.LiveTV.RecordingNotifier. Duration: 0.0064317 seconds
Info App: Starting entry point Emby.ActivityLog.ActivityLogEntryPoint
Info App: Entry point completed: Emby.ActivityLog.ActivityLogEntryPoint. Duration: 0.0096611 seconds
Info App: Starting entry point Emby.Server.MediaEncoding.Api.EncodingManagerEntryPoint
Info LibraryMonitor: Watching directory with new FileSystemWatcher for /media/Documentary for item 5122
Info App: Entry point completed: Emby.Server.MediaEncoding.Api.EncodingManagerEntryPoint. Duration: 0.0233859 seconds
Info App: Starting entry point Emby.Notifications.NotificationManagerEntryPoint
Info Notifications: Registering event nofitier Emby Server User Notifications
Info App: Entry point completed: Emby.Notifications.NotificationManagerEntryPoint. Duration: 0.0399851 seconds
Info App: Starting entry point Emby.Server.Sync.SyncNotificationEntryPoint
Info App: Entry point completed: Emby.Server.Sync.SyncNotificationEntryPoint. Duration: 0.0053606 seconds
Info App: Starting entry point EmbyServer.Windows.LoopUtilEntryPoint
Info App: Entry point completed: EmbyServer.Windows.LoopUtilEntryPoint. Duration: 0.0003221 seconds
Info App: All entry points have started
s6-svscanctl: fatal: unable to control /var/run/s6/services: supervisor not listening
[cont-finish.d] executing container finish scripts...
[cont-finish.d] done.
[s6-finish] waiting for services.
[s6-finish] sending all processes the TERM signal.
[s6-finish] sending all processes the KILL signal and exiting.
Any ideas would be appreciate..
The text was updated successfully, but these errors were encountered: