styxadmin commented Mar 12, 2021

Zabbix Server 5.0.7

Zabbix Agent 5.0.9

Debian 10

Copied the userparameter_cputemp.conf into /etc/zabbix/zabbix_agentd.d/

Template has been linked to the host. I also tested the commands in the userparameter config file which work 100%

EDIT: Seems like it is an Unsupported item key

basicCPUTemp-Unsupported

@randommen96
Copy link

Not sure if you ever solved it, but I just implemented it as is on my zabbix 6.0 server and debian 11 (proxmox) and it works just fine :-), just so you know.

I like it, plain simple.

@styxadmin
Copy link
Author

Not sure if you ever solved it, but I just implemented it as is on my zabbix 6.0 server and debian 11 (proxmox) and it works just fine :-), just so you know.

I like it, plain simple.

Thank you, I have not tried it again since posting this

Guess I'll give it another go on Zabbix 6

@fromage9747
Copy link

@styxadmin Any luck? I have implemented it today and no data is being pulled.

@fromage9747
Copy link

the File userparameter_cputemp.conf causes the Zabbix Agent to fail and will not start whilst it exists

@ItzDerock
Copy link

Was able to solve this issue by changing the grep Core in the userparams file to match what I found from running sensors.

In my case, running sensors returns:

root@goliath:~# sensors
gigabyte_wmi-virtual-0
Adapter: Virtual device
temp1:        +50.0°C  
temp2:        +55.0°C  
temp3:        +66.0°C  
temp4:        +21.0°C  
temp5:        +54.0°C  
temp6:        +54.0°C  

acpitz-acpi-0
Adapter: ACPI interface
temp1:        +16.8°C  (crit = +20.8°C)
temp2:        +16.8°C  (crit = +20.8°C)

k10temp-pci-00c3
Adapter: PCI adapter
Tctl:         +66.1°C  
Tccd1:        +65.2°C  
Tccd2:        +60.0°C 

In the above, the CPU temperature is reported under k10temp-pci-00c3 as Tctl, Tccd1, and Tccd2, which all start with a T so I changed the grep Core to grep T. After restarting zabbix_agent2, I could start to see data.